Standard Materials for Structured Cabling (568) Systems
Four-pair 100 ohm UTP cables
The cable consists of 24 AWG thermoplastic insulated conductors formed into four individually twisted pairs and enclosed by a thermoplastic jacket. Four-pair, 22 AWG cables which meet the transmission requirements may also be used. Four-pair, shielded twisted pair cables which meet the transmission requirements may also be used.
The diameter over the insulation shall be 1.22mm (0.048 in) max.
The pair twists of any pair shall not be exactly the same as any other pair. The pair twist lengths shall be selected by the manufacturer to assure compliance with the crosstalk requirements of this standard.
| Color Codes | |
|---|---|
| Pair 1 White-Blue (W-BL) | Blue (BL)" |
| Pair 2 White-Orange (W-O) | Orange (O)" |
| Pair 3 White-Green (W-G) | Green (G)" |
| Pair 4 White-Brown (W-BR) | Brown (BR)" |
Cable Specifications:
- The diameter of the completed cable shall be less than 6.35mm (0.25in)
- The ultimate breaking strength of the completed cable is 90 lb minimum. Maximum pulling tension should not exceed 25 lb to avoid stretching.
- The cable tested shall withstand a bend radius of 25.4mm (1in) at a temperature of -20C without jacket or insulation cracking.
- The resistance of any conductor shall not exceed 28.6 ohms per 305m (1000ft.) at or corrected to a temperature of 20C.
- The resistance unbalance between the two conductors of any pair shall not exceed 5% when measured at or corrected to a temperature of 20C in...
- The mutual capacitance of any pair at 1kHz shall not exceed 20 nF per 305 M (1000ft.)
- The mutual capacitance of any pair at 1 kHz and measured at or corrected at a temperature of 20C, shall not exceed 17 nF per 305 m (1000ft) for category 4 and category 5 cables.
- the capacitance unbalance to ground at 1 kHz of any pair shall not exceed 1000 pF per 305m (1000ft.).
Guides
- Lamp Guide: General Information
- Lamp Guide: Fluorescent
- Lamp Guide: HID
- Lamp Guide: Incandescent
- Line Noise
- Power Surges and Spikes
- Brownouts
- Blackouts
- Heat Dissipation in Electrical Enclosures
- Hazardous Location Basics
- Basic Proximity Sensor Operations
- Occupancy Sensor Design Guide
- Occupancy Sensor Application Guide
- Color Application for HID Lamps
- Cutler-Hammer Heater Coil
- General Electric Heater Coil
-
Electrical Tables
- Allowable Ampacities Insulated Conductors
- Conduit Fill Table
- NEMA Straight Blade Configs
- NEMA Locking Blade Configs
- Common Conversion Factors
- Derate 3 Conductors in a Raceway
- Direct Current Motor Full Load Current
- Approximate Full Load Amperes
- Full Load Current: Three Phase AC Motors
- Full-Load Current: Single Phase AC Motors
- Specific Resistance
- Temperature Conversion Table
- UL Fuse Classification Chart
- Buck Boost Transformer Full Load Amps
-
Calculations
- Ohm's Law
- Electrical Formulas
- Full Load Formula
-
Datacomm Tables
- Attenuation for Coaxial and UTP Cables
- Backbone Runs: UTP Cable
- Basic/Channel Link Attenuation
- Basic/Channel Link Next Loss
- Cable Administration
- Category Cables
- Circuit Protection
- Common Ethernet Systems
- Common Types of Cabling
- Computer Circuits
- Copper Wire Limitations
- Digital Patch Cable (DPC) Coding
- 10Base-T Crossover Patch Cord
- 10Base-T Straight Thru Patch Cord
- General Cable Installation Rules
- UTP Cable Attenuation
- Installing Category Data Cables
- Parameters of EIA/TIA 568
- Separation from Sources of Interference
- Structured Cabling (568) Systems
- Standard Networking Configurations
- Telecommunication Outlet Specifications
- UTP Connecting Hardware